MicroCal PEAQ-DSC: the future of protein stability characterization

Setting the new gold standard for protein stability characterization: MicroCal PEAQ-DSC – Differential Scanning Calorimetry for the regulated environment. This innovation from Malvern Panalytical gives you data you can trust, allowing you to make confident decisions on your biological molecules at any stage of development – from candidate selection all the way through to biosimilarity assessment or manufacture. _x000D_
_x000D_
The MicroCal PEAQ-DSC is the ultimate platform for stability assessment – one technology which provides high-throughput, automated operation and analysis for all users._x000D_
_x000D_
Read more about the MicroCal DSC range: https://www.malvernpanalytical.com/en/products/product-range/microcal-range/microcal-dsc-range

What Is Differential Scanning Calorimetry (DSC)?

The MicroCal DSC team introduce what Differential Scanning Calorimetry (DSC) is and why it is the gold standard in characterizing the stability of a protein or other biomolecules. _x000D_
_x000D_
The MicroCal team details how Differential Scanning Calorimetry (DSC) works and why you should be using it for testing protein stability._x000D_
_x000D_
For more information on Scanning Calorimetry (DSC) here http://www.malvernpanalytical.com/en/products/technology/differential-scanning-calorimetry/default.aspx

MicroCal PEAQ-DSC – The Gold Standard for protein stability characterization

This video describes the advantages of using MicroCal Differential Scanning Calorimetry (DSC) for protein stability characterization in comparison with other analysis techniques_x000D_
_x000D_
For more Information visit: https://www.malvernpanalytical.com/en/products/product-range/microcal-range/microcal-dsc-range

MicroCal DSC – Manufacturing and Process Development

Ensure the consistent quality of biopharmaceutical formulations throughout the manufacturing process using MicroCal Differential Scanning Calorimetry (DSC), the gold standard for thermal stability characterization.

Understand and minimize protein aggregation whilst developing and manufacturing your biotherapeutic product by monitoring the protein’s transition midpoint temperature – Tm – using Differential Scanning Calorimetry, the gold standard in thermal stability characterization of biopharmaceuticals.

https://www.malvernpanalytical.com/en/products/product-range/microcal-range/microcal-dsc-range/

A scientist’s view on using microcalorimetry to assess thermostability

Here is the newest version of the video showing Katherine Bowers, Lead Formulation Development Scientist at FUJIFILM Diosynth Biotechnologies. She shares her views on Differential Scanning Calorimetry. _x000D_
_x000D_
Her team uses a MicroCal VP-Capillary DSC system for looking at thermal stability of protein molecules, for formulation development, for biophysical characterization and during process development support. Find out more about the Malvern Panalytical MicroCal DSC range here: http://bit.ly/MicroCalDSC

Malvern MicroCal DSC – Formulation stability testing

Biopharmaceutical Formulation Stability Testing – using Differential Scanning Calorimetry (DSC)_x000D_
_x000D_
https://www.malvernpanalytical.com/en/products/product-range/microcal-range/microcal-dsc-range/_x000D_
_x000D_
See how Differential Scanning Calorimetry (DSC) helps with biopharmaceutical formulation characterization from candidate molecule through to final drug product. Understand why MicroCal Differential Scanning Calorimetry (DSC) is the gold standard for thermal stability characterization of biotherapeutic formulations. Ensuring good thermal stability is vital so that the protein remains safe and effective throughout the shelf life of the product. _x000D_
_x000D_
Differential Scanning Calorimetry (DSC) helps measure the stability of proteins.

Principles of isothermal titration calorimetry (ITC)

Introduction to the principles of isothermal titration calorimetry & Microcell’s ITC microcalorimeter. View the Malvern Panalytical Range of ITC solutions.

http://www.malvernpanalytial.com/en/products/technology/isothermal-titration-calorimetry/default.aspx

Nanoparticle Tracking Analysis – NanoSight in 90 Seconds

The Malvern Panalyitcal NanoSight range of instruments utilizes Nanoparticle Tracking Analysis (NTA) to characterize nanoparticles including exosomes, from 10nm -2000nm* in solution. _x000D_
_x000D_
Visit the website for more information: https://www.malvernpanalytical.com/en/products/product-range/nanosight-range/_x000D_
_x000D_
Each particle is individually, but simultaneously analyzed by direct observation and measurement of diffusion events. _x000D_
_x000D_
This particle-by-particle methodology produces high resolution results for particle size distribution and count, while visual validation provides users with additional confidence in their data._x000D_
_x000D_
Both particle size and count are measured, while a fluorescence mode provides differentiation of labelled or naturally fluorescing particles.

NanoSight Pro: Expert Nanoparticle Tracking Analysis

The quickest, easiest and most detailed NTA solution to characterization bio and nano materials. Discover the Malvern Panalytical NanoSight Pro: https://www.malvernpanalytical.com/products/product-range/nanosight-range/nanosight-pro/

NanoSight Pro Remote Demo

Learn how to setup and use the NanoSight Pro in real time.

Key software features including fluorescence and auto setup will be highlighted to show you how quick, easy and accurate it is to obtain size and concentration data of nanoparticles.

This demo will walk you through how to obtain size and concentration data of fluorescently labelled exosomes. It also highlights the ease of comparing different samples and quality assurance of your data.

Want to learn more about NanoSight Pro? https://www.malvernpanalytical.com/en/products/product-range/nanosight-range/nanosight-pro